December 23, 2020 | Baton Rouge, LA
sewer back up coming from the laundry room which is also a bathroom (category 3). Rooms affected are: Kitchen/dining room, office, living room, hallway, foyer, laundry room, movie room, and bedroom 1. Floors are significantly damaged and need to be removed along with baseboards and drywall in some areas. One dehu, ...

December 22, 2020 | Lake Charles, LA
In addition to the mold, the team found that the air conditioning system was running in cooling mode, which contributed to elevated humidity levels. The dehumidifier was running at peak capacity, registering moisture levels between 90% and 100%. UFW also identified significant moisture damage to the baseboards along the south and eastern-facing ...

December 22, 2020 | Lake Charles, LA
During the inspection, it was noted that one area of the sill plate was still wet, with a moisture reading of 27. The team determined that this area would need further attention, as excessive moisture in the sill plate could lead to structural issues if not properly dried. Additionally, some of ...

December 16, 2020 | Baton Rouge, LA
we removed the floors from the dinning room and was in the in the process of scrapping up the glue. a little demo has started was only able to get to a few things today as a cutting out the 2 foot flood cut in the laundry and bathroom. placed 3 dehumidifiers, 3 ...

December 10, 2020 | Baton Rouge, LA
Need to cut open wall and get at least one dehu and 1-2 fans out to stabilize. Removed 6sf. Drywall, clean and setup 1 fan, 1 neg. air fan and a DH. Neither the venting nor the gravity drain-line with p-trap is properly installed up to code in the home with proper ...

December 7, 2020 | Baton Rouge, LA
I put in 5 fans, 1 neg. Air and 1 DH. We need 3 axial fans in here for the ceiling and 5 laminar air movers for the baseboards and vanity. one fan in the attic blowing down. there are 3 additional rooms affected. the laminate in each room (master bedroom, office, and guest bedroom) pulled. ...

December 3, 2020 | Lake Charles, LA
In the upstairs Office Gym, moisture readings were high in one of the walls, prompting UFW to set up additional drying equipment. To address the moisture in this area, one dehumidifier and two air movers were placed to ensure effective drying. Given the extent of the moisture readings and the ...

November 11, 2020 | Denham Springs, LA
To mitigate the water damage in this Denham Springs, LA, property, we set up five dehumidifiers, three air movers, and three air scrubbers to expedite drying and improve air quality. Mitigation efforts included the removal of all lower cabinets, the carpet, and the padding in the affected areas. These steps ...

November 11, 2020 | Lake Charles, LA
To address the moisture issue, UFW deployed three dehumidifiers, three air movers, and one air scrubber to help dry out the affected areas. This equipment is expected to run for seven days to fully eliminate excess moisture from the interior, preventing further damage and the growth of mold or mildew. ...